Multi-jackbolt tensioners replace the hex nut on the joints that cannot leak. No hammer wrench, no hydraulic torque, no hot work.
A Superbolt tensioner threads onto the existing stud in place of the hex nut. Instead of turning one large nut against friction, you tighten a ring of small jackbolts.

Torque is not tension. Tension is what seals the joint.
In June 2018 we surveyed the assembly and start-up of a high-pressure compression module at the POL-A process centre. Flanges from 2 to 36 inches were bolted at night, in tight spaces, with hammer wrenches and hydraulic torque. Every leak at start-up meant re-tightening and deferred production.
Our own measurements on the platform, against hydraulic torque on the same flange.
We installed Superbolt on the compression-module joints with our own crew on board and a torque audit of every tensioner.
| Joint | Size |
|---|---|
| Flanging module | 36" · 600# |
| V-101 manway | 30" · 300# |
| V-101 inlet and outlet | 24" · 300# |
| Retention cones, module 1 | 24" · 150# and 14" · 300# |
| PSV, fuel gas, drains and spools | 2"–8" · 150–300# |



Zero leaks. Zero re-tightening. Two days back at every start-up.
The BOP is the last barrier between the well and the crew. Its joints are high-pressure, metal ring-gasket connections, in places where a hydraulic wrench does not fit and nobody wants a hammer wrench.
| Joint | What applies |
|---|---|
| Stack flanges: annular, rams, spools and wellhead | Superbolt · Boltight |
| Ram bonnets and doors | Superbolt |
| Choke and kill lines, choke manifold | Superbolt |
| Top drive, mud pumps, drawworks | Superbolt · Nord-Lock washers |
Every BOP change is rig time. Several technicians tighten at once with hand wrenches.
Even load on the metal ring gasket, so the pressure test passes without re-tightening.
No hammer wrench, no high-pressure hoses and no heavy gear in a confined space.
A torque audit of every tensioner, recorded for the joint file.
Application examples from Nord-Lock Group in oil and gas. BOP manufacturers already use multi-jackbolt tensioners and wedge-locking washers.


The last barrier on the rig deserves a known preload.
Turbine joints are large, hot and hard to reach. Superbolt loads them evenly without heating the bolts and without impact tools.






No bolt heaters. No hammer wrenches. Just a torque wrench.
A wind turbine is bolted together from the foundation to the blade tips, and most of that work happens in a nacelle with no room for heavy tooling.
| Joint | Why Superbolt |
|---|---|
| Main shaft and rotor hub | High preload in a space where a hydraulic wrench does not fit |
| Gearbox and generator mounts | Holds preload under vibration and load reversals |
| Blade and yaw bearings | Even load around the full bolt circle |
| Tower flanges and foundation anchors | Large diameters tightened with hand tools |
Nothing heavy to lift up the tower.
For full bolt circles, Typhoon+ hydraulic tensioners are stocked in North America and ship in 48 hours.
Application examples from Nord-Lock Group in wind.